Acrel-2000MG Micro-grid Energy Management System

 System Introduction

Acrel microgrid energy management system, Acrel-2000MG, accommodates the integration of photovoltaic systems, energy storage systems, and other equipment, performing around-the-clock data collection and analysis. It monitors the operational status and health condition of photovoltaic, energy storage, and other systems, serving as a comprehensive management system that integrates monitoring and energy management. This system aims for economic optimization based on safety and stability, promoting the utilization of renewable energy, peak shaving, load leveling, improving grid operational stability and equipment operational efficiency, and reducing power supply costs. It provides a new solution for the safe, reliable, and economical operation of enterprise microgrids.

 System Functions

System overview

Equipment Monitoring

Power Forecasting

Optimization Control

Economic Dispatch

Energy Analysis

2000MG structure

Application

2000MG application - 1
2000MG application - 2
2000MG application - 3
2000MG application - 4

Acrel-2000MG Micro-grid Energy Management System Advantages

2000MG All System Management

All System Management

Acrel-2000MG could integrate and manage with all type of power system like ESS, Solar PV, Wind Power, Diesel Generator, EV Charger, traditional Grids and etc.

The power monitoring of the highway power supply and distribution system should include comprehensive monitoring of power in areas such as tunnel substations, service area substations, toll station substations, box type substations along the line, and interchange hubs.

2000MG Peak-Valley Arbitrage

Peak-Valley Arbitrage

By using the energy management and control plan of Acrel-2000MG, we could realize peak shaving &valley filling energy usage strategy for peak-valley arbitrage. Benefit of peak-valley arbitrage could be check in Acrel-2000MG energy management system.

2000MG Back-up Power Source

Power Demand Control

Acrel-2000MG could set a power demand threshold and manage all the power system in micro-grids so that the overall loads power demand won't exceed this limitation value. No extra fine happened due to exceeding the power demand.

2000MG Power Demand Control

Back-up Power Source

Acrel-2000MG EMS system could set the plan for back-up power source to prevent the influence of unpredicable power outage.

Acrel-2000MG Micro-grid Energy Management System Software Overview

System Homepage

Homepage include a general view of site actual micro-grids power system situation. Energy consumption situation, carbon dioxide emission info, profit gain from control plan and new energy, weather station info, power curve and etc.

2000MG System Homepage

Profit Analysis

Analysis about how much profit gained from peal-valley arbitrage strategy, new energy power generation profit and etc.

2000MG Profit Analysis

Visualized Operation

Providing topology according to actual site situation. Real-time data and status for you to realize a simple and visualized maintenance.

2000MG Visualized Operation

Solar PV Monitoring

General monitoring for solar PV system including solar PV power generation and profit gained by it. Weather station information, voltage&current&power curve and etc.Grid-connected power quality monitoring and analysis

2000MG Solar PV Monitoring

Wind Power Monitoring

General monitoring for wind power system including wind power generation and profit gained by it. Weather station information, voltage&current&power curve and etc.Grid-connected power quality monitoring and analysis.

2000MG Wind Power Monitoring

ESS Monitoring

General monitoring for ESS energy storage system including charging&discharging power, energy, status information. Also, the SOC curve, PCS&BMS status could be all checked in Acrel-2000MG. Also, the operation mode could be changed between peak-valley mode, scheduled curve, demand control, etc.

2000MG ESS Monitoring

EV Charger Monitoring

General monitoring for EV charger including charging energy, profit gain by EV charger. Also, the detail working status, voltage, current, charging amount of each EV charger could be checked.

2000MG EV Charger Monitoring

Power Quality Analysis

Continuously monitor the power quality and reliability status of power system, including steady-state data such as voltage harmonics, voltage flicker, and voltage imbalance, as well as transient data like voltage sags/swells, voltage interruptions, and transient voltage data. Perform monitoring, analysis, and waveform recording of these parameters, and also monitor transient voltage and current events.

2000MG Power Quality Analysing

Optimized Power Control

Acrel-2000MG could set various control plan to realize optimized power operation for saving your money and make profit. Such as peak-valley arbitrage, max demand control and etc

2000MG Optimized Power Control

Acrel-2000MG Micro-grid Energy Management System Hardware Overview

2000MG hardware - 1

ANET Seires

IoT Gateway

The ANET series IoT gateway utilizes an embedded hardware computing platform and features multiple downstream communication interfaces and multiple upstream network interfaces. It is designed to aggregate and organize communication data from all intelligent monitoring/protection devices within a target area and upload it in real-time to the master station system. This setup completes the functions of remote signaling and remote measurement for energy data collection.

2000MG hardware - 2

ADL3000-E Series

3-phase DIN-rail Multi-function Energy Meter

The ADL3000-E is an intelligent electric meter specifically designed for power supply systems, industrial and mining enterprises, and utility companies. It is used to calculate electricity consumption and manage electrical demand. Key features include high accuracy, compact size, and easy installation. The device integrates measurement of all electrical parameters and comprehensive power metering management, providing data for the past 12 months. It can check the content of up to 31 harmonics and total harmonic distortion. Remote communication and control are enabled through digital inputs and relay outputs, and it also features alarm outputs. The ADL3000-E is suitable for various control systems, SCADA systems, and energy management systems. All instruments comply with the relevant technical requirements of IEC62053-21 and IEC62053-22 standards for power meters.

2000MG hardware - 3

APView500 Seires

Power Quality Analyser

Utilizing a high-performance multi-core platform and an embedded operating system, it adheres to the measurement methods for power quality indicators specified in IEC61000-4-30 and follows the IEC61000-4-15 standard. The system integrates functions such as harmonic analysis, waveform sampling, voltage sag/swell/interruption monitoring, flicker monitoring, voltage imbalance monitoring, event recording, and measurement control into one unit.

2000MG hardware - 4

AM5SE Series

Medium-voltage Protection Relay

The AM5SE series microcomputer protection and control devices integrate protection, control, measurement, communication, and monitoring functions into one unit. They feature rich resources, comprehensive configuration, easy maintenance, and stable performance, making them suitable for protection and control of power systems with voltage levels of 35kV and below. These devices provide protection for incoming lines, main transformers, distribution transformers, motors, capacitors, bus couplers, and PTs. The application areas include power, water conservancy, transportation, petroleum, chemical, coal, metallurgy, and new energy industries.

Typical Cases & On-site Pictures

Ready to get started? Contact us today for a free quote!

Prêt à commencer ? Contactez-nous dès aujourd'hui pour un devis gratuit !


Post time: Sep-19-2024