Background
This article introduces the application of the Hall Sensor used in Indonesia. Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signal control of current signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature quick response, a wide range of measurements, high precision, strong overload capacity, good linearity and excellent anti-interference performance.
Project Overview
The company in Indonesia that makes the traffic light system and needs to use a DC hall sensor to transmitter the DC current to 4-20mA analog signal output. After they choose the hole size, input ratio, output ratio and working power supply, the customer chosen the AHKC-EKAA as their best choice.
Classification
Hall sensors are divided into three categories according to the principle: open-loop Hall current sensor, closed-loop Hall current sensor, Hall voltage sensor.
Type | Rated Input | Rated Output | Power Supply | Accuracy |
Open-loop Hall sensor | 50A~20000A | 5V/4~20mA | ±15V/24V | class1 |
Closed-loop Hall sensor | 10A~2000A | 50mA/100mA/200mA | ±15V | class0.5 |
Hall voltage transducer | 100V~5000V | 5V/50mA | 15V/24V | class0.5 |
Application
Photovoltaic
UPS
Solar and wind energy
Electric welding machine
Motor servo system
Rectifier
Main Functions
Type | Picture | Function |
Open loop Hall sensor | 1. Class1 2. Easy installation 3. Input range width:50A-20000A 4. Output: 4V/5V/20mA/4-20mA |
|
Closed-loop Hall sensor | 1. Class0.5 2. Input:10A-2000A 3. Fast response time≤1us 4. bandwidth:≤100kHz |
|
Hall voltage transducer | 1. Class0.5 2.Input:100-5000V 3. Fast response time≤200us 4. bandwidth:≤100kHz |
Product Selection
Shape | Type | Rated
Input |
Rated
Output |
Measuring Aperture | Power Supply | Application |
AHKC-EKA | 0-(50-500)A | 5V/4V | 20mm | ±15V | 1. Photovoltaic DC cabinet2. photovoltaic inverter/wind inverter
3. The data cente |
|
AHKC-EKAA | DC 0-(50-500)A | 4-20mA | 20mm | 12V/24V | ||
AHKC-BS | 0-(50-500)A | 5V/4V | 20.5*10.5mm | ±15V | ||
AHKC-E | 0-(200-500)A | 5V/4V | 20mm | ±15V | ||
AHKC-F | 0-(200-1000)A | 5V/4V | 43*13mm | ±15V | ||
AHKC-K | 0-(400-2000)A | 5V/4V | 64*16mm | ±15V | ||
AHLC-LTA | 100A-300A | 50mA/100mA | 20mm | ±15V | UPS | |
AHBC-LF | 2000A | 400mA | / | ±12V~±24V | 1. UPS
2. photovoltaic inverter |
|
AHBC-LT1005 | 1000A | 200mA | / | ±12V~±24V | UPS |