Acrel AHKC-EKC Split Core Hall Effect Current Sensor

Acrel AHKC-EKC Split Core Open-loop Hall Effect Current Sensor

 

● Input: AC/DC 0~(500-1500)A

● Output: 5V/4V, 4-20mA

● Auxiliary Power: ±15V, 12V/24V

● Internal Diameter: φ 55mm


Product Detail

Technical Parameters

Download

Product Tags

Acrel AHKC-EKC Split Core Hall Effect Current Sensor

General

Acrel AHKC series hall effect current sensor is mainly suitable for the isolation conversion of complex signals such as AC, DC, and pulse. Through the Hall effect principle, the converted signal can be directly collected and accepted by various acquisition devices such as AD, DSP, PLC, and secondary instruments, fast response time, wide current measurement range, high precision, strong overload capacity, good linearity, and strong anti-interference ability.

Acrel AHKC-EKC Hall Sensor is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.

Dimension of AHKC-EKC Split Core Hall Effect Current Sensor

dimension-of-ahkc-ekb-split-core-hall-effect-current-sensor

Wiring

Hall Sensor Wiring - 1_副本
Hall Sensor Wiring - 2_副本
Hall Sensor Wiring - 3_副本

Installation of AHKC-EKC Split Core Hall Effect Current Sensor

installation-of-ahkc-eka-split-core-hall-effect-current-sensor

Precautions of AHKC-EKC Split Core Hall Effect Current Sensor

When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram the thread hole of Hall sensor module completely is proposed to use.

When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot be more than 80℃.

When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of calibration value.

The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use.

Zero and full scale regulator potentiometer can not be adjusted.

Auxiliary power supply is required to be deployed voluntarily.

Power positive and negative poles cannot be inversely connected.

Application of AHKC-EKC Split Core Hall Effect Current Sensor

Current monitoring and battery applications

Inverter power supply and solar power management system

DC screen and DC motor drive, electroplating, welding applications

Frequency converter, UPS servo control and other system current signal acquisition and feedback control


  • Previous:
  • Next:

  • Acrel AHKC-EKC Split Core Open-loop Hall Effect Current Sensor

    Technical Parameters

     Parameters Parameters 
    Rated Input Current 0~(500-1500)A
    Rated Output Voltage ±5V/±4V
    Accuracy Class 1.0
    Power Voltage DC ±15V (allowable fluctuation±20%)
    Zero Offset Voltage ±20mV
    Offset Voltage Drift ≤±1.0mV/℃
    Linearity ≤0.2%FS
    Response Time ≤5us
    Bandwidth 0~20kHz
    Isolation Voltage 3.5kV/50Hz/1min
    Operating Temperature -40℃~85℃
    Storage Temperature -40℃~85℃
    Consumption ≤0.5W

    1. Manual for Acrel AHKC-EKC Split Core Open-loop Hall Effect Current Sensor

    2. Installation and Use for Acrel AHKC-EKC Split Core Open-loop Hall Effect Current Sensor

    3. Debugging Software for Acrel AHKC-EKC Split Core Open-loop Hall Effect Current Sensor

    Write your message here and send it to us